Sulphiting agents are a class of compounds that are used as preservatives since they release SO2 in food. Regarding meat products, the legislation restricts the use of these food additives, due to some toxic effects that they may have in humans. The most employed analytical procedure for the determination of sulphiting agents in foodstuffs is the Monier-Williams (M-W) method, but the reliability of this method was called into question by several authors. In this work, the M-W method was modified by replacing both the distillation unit to shorten the extraction time (from hours to 5 min) and the final titration with a chromatographic separation followed by conductometric detection of sulphate ion (m-M-W/IC-CD). This method was then validated, and the performance parameters were compared with those of the method based on the direct analysis of sulphite ion by ion chromatography with conductometric detection (DIC-CD). Linearity, accuracy at 40 and 80 mg kgâ1 of SO2 and measurement uncertainty resulted comparable. Accuracy at 10 mg kgâ1 of SO2 resulted higher for the m-M-W/IC-CD method, but this parameter could be influenced by traces of other sulphur-containing compounds that may be present in meat. The limit of determination of the m-M-W/IC-CD method was slightly higher than that obtained by the DIC-CD method. Finally, through spiking tests, it was proved that sulphide, 2-methyl-3-furanthiol and l-methionine cause âfalse-positiveâ responses, by using M-W-based methods.
Determination of Sulphiting Agents in Raw and Processed Meat: Comparison Between a Modified Monier-Williams Method and the Direct Analysis by Ion Chromatography with Conductometric Detection
Iammarino, Marco;Centonze, Diego
2017-01-01
Abstract
Sulphiting agents are a class of compounds that are used as preservatives since they release SO2 in food. Regarding meat products, the legislation restricts the use of these food additives, due to some toxic effects that they may have in humans. The most employed analytical procedure for the determination of sulphiting agents in foodstuffs is the Monier-Williams (M-W) method, but the reliability of this method was called into question by several authors. In this work, the M-W method was modified by replacing both the distillation unit to shorten the extraction time (from hours to 5 min) and the final titration with a chromatographic separation followed by conductometric detection of sulphate ion (m-M-W/IC-CD). This method was then validated, and the performance parameters were compared with those of the method based on the direct analysis of sulphite ion by ion chromatography with conductometric detection (DIC-CD). Linearity, accuracy at 40 and 80 mg kgâ1 of SO2 and measurement uncertainty resulted comparable. Accuracy at 10 mg kgâ1 of SO2 resulted higher for the m-M-W/IC-CD method, but this parameter could be influenced by traces of other sulphur-containing compounds that may be present in meat. The limit of determination of the m-M-W/IC-CD method was slightly higher than that obtained by the DIC-CD method. Finally, through spiking tests, it was proved that sulphide, 2-methyl-3-furanthiol and l-methionine cause âfalse-positiveâ responses, by using M-W-based methods.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.