Mitral valve regurgitation which occurs immediately after repair can be due to anatomic (failure of repair) or functional (systolic anterior motion) reasons. We report a case where a patient with bileaflet prolapse showed, after surgical correction of the disease, moderate to severe regurgitation after cardiopulmonary bypass was stopped. The regurgitation was due to second-order tethering and was successfully treated with second-order chordal cutting. © 2013 by The Society of Thoracic Surgeons.

Intermittent tethering of second-order chords after mitral valve repair for bileaflet prolapse

Di Mauro M.;
2013-01-01

Abstract

Mitral valve regurgitation which occurs immediately after repair can be due to anatomic (failure of repair) or functional (systolic anterior motion) reasons. We report a case where a patient with bileaflet prolapse showed, after surgical correction of the disease, moderate to severe regurgitation after cardiopulmonary bypass was stopped. The regurgitation was due to second-order tethering and was successfully treated with second-order chordal cutting. © 2013 by The Society of Thoracic Surgeons.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11369/478915