Background: Both general anesthesia and pneumoperitoneum insufflation during abdominal laparoscopic surgery can lead to atelectasis and impairment in oxygenation. Setting an appropriate level of external PEEP could reduce the occurrence of atelectasis and induce an improvement in gas exchange. However, in clinical practice, it is common to use a fixed PEEP level (i.e., 5 cmH(2)O), irrespective of the dynamic respiratory mechanics. We hypothesized setting a PEEP level guided by EIT in order to obtain an improvement in oxygenation and respiratory system compliance in lung-healthy patients than can benefit a personalized approach. Methods: Twelve consecutive patients scheduled for abdominal laparoscopic surgery were enrolled in this prospective study. The EIT Timpel Enlight 1800 was applied to each patient and a dedicated pneumotachograph and a spirometer flow sensor, integrated with EIT, constantly recorded respiratory mechanics. Gas exchange, respiratory mechanics and hemodynamics were recorded at five time points: T0, baseline; T1, after induction; T2, after pneumoperitoneum insufflation; T3, after a recruitment maneuver; and T4, at the end of surgery after desufflation. Results: A titrated mean PEEP of 8 cmH(2)O applied after a recruitment maneuver was successfully associated with the "best" compliance (58.4 +/- 5.43 mL/cmH(2)O), with a low percentage of collapse (10%), an acceptable level of hyperdistention (0.02%). Pneumoperitoneum insufflation worsened respiratory system compliance, plateau pressure, and driving pressure, which significantly improved after the application of the recruitment maneuver and appropriate PEEP. PaO2 increased from 78.1 +/- 9.49 mmHg at T0 to 188 +/- 66.7 mmHg at T4 (p < 0.01). Other respiratory parameters remained stable after abdominal desufflation. Hemodynamic parameters remained unchanged throughout the study. Conclusions: EIT, used as a non-invasive intra-operative monitor, enables the rapid assessment of lung volume and regional ventilation changes in patients undergoing laparoscopic surgery and helps to identify the "optimal" PEEP level in the operating theatre, improving ventilation strategies.

Electrical Impedance Tomography during Abdominal Laparoscopic Surgery: A Physiological Pilot Study

Rauseo, Michela;Spadaro, Savino;Mirabella, Lucia;Cotoia, Antonella;Laforgia, Donato;Gaudino, Gennaro;Vinella, Francesca;Ferrara, Giuseppe;Gattullo, Adriana;Tullo, Livio;Cinnella, Gilda
2023-01-01

Abstract

Background: Both general anesthesia and pneumoperitoneum insufflation during abdominal laparoscopic surgery can lead to atelectasis and impairment in oxygenation. Setting an appropriate level of external PEEP could reduce the occurrence of atelectasis and induce an improvement in gas exchange. However, in clinical practice, it is common to use a fixed PEEP level (i.e., 5 cmH(2)O), irrespective of the dynamic respiratory mechanics. We hypothesized setting a PEEP level guided by EIT in order to obtain an improvement in oxygenation and respiratory system compliance in lung-healthy patients than can benefit a personalized approach. Methods: Twelve consecutive patients scheduled for abdominal laparoscopic surgery were enrolled in this prospective study. The EIT Timpel Enlight 1800 was applied to each patient and a dedicated pneumotachograph and a spirometer flow sensor, integrated with EIT, constantly recorded respiratory mechanics. Gas exchange, respiratory mechanics and hemodynamics were recorded at five time points: T0, baseline; T1, after induction; T2, after pneumoperitoneum insufflation; T3, after a recruitment maneuver; and T4, at the end of surgery after desufflation. Results: A titrated mean PEEP of 8 cmH(2)O applied after a recruitment maneuver was successfully associated with the "best" compliance (58.4 +/- 5.43 mL/cmH(2)O), with a low percentage of collapse (10%), an acceptable level of hyperdistention (0.02%). Pneumoperitoneum insufflation worsened respiratory system compliance, plateau pressure, and driving pressure, which significantly improved after the application of the recruitment maneuver and appropriate PEEP. PaO2 increased from 78.1 +/- 9.49 mmHg at T0 to 188 +/- 66.7 mmHg at T4 (p < 0.01). Other respiratory parameters remained stable after abdominal desufflation. Hemodynamic parameters remained unchanged throughout the study. Conclusions: EIT, used as a non-invasive intra-operative monitor, enables the rapid assessment of lung volume and regional ventilation changes in patients undergoing laparoscopic surgery and helps to identify the "optimal" PEEP level in the operating theatre, improving ventilation strategies.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11369/456969
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact