Objectives Evaluating the efficacy of 2 new percutaneous devices specifically designed to be placed through the right internal jugular vein, therefore named “necklines,” for achieving retrograde cardioplegia and pulmonary venting in the setting of minimally invasive aortic valve replacement (MIAVR). Design Case series. Setting University-affiliated private hospital. Participants Patients undergoing MIAVR. Interventions Necklines were placed by the anesthesiologist using transesophageal electrocardiography, with pressure guidance before the surgical procedure was initiated. Measurements and Main Results The records of 51 consecutive patients who underwent MIAVR with necklines placement were reviewed retrospectively. The access for MIAVR was through either a J-hemisternotomy or a right anterior thoracotomy. The efficacy of the 2 catheters, successful placement rate, time needed to deploy catheters, and perioperative complications were recorded. Necklines were placed successfully in all patients in 23±13 minutes. A total of 110 doses of retrograde cardioplegia were delivered at a mean flow rate of 173±35 mL/min and a mean pressure of 41±6 mmHg. The pulmonary catheter ensured venting of the heart that was graded by surgeons as “excellent” in 33 patients, “sufficient” in 12 patients, and “not adequate” in 2 patients. There were no major adverse events or deaths. Conclusions Necklines ensure effective retrograde cardioplegia and venting of the heart, provide optimal surgical vision and access during MIAVR, and allow surgeons to operate in an unobstructed surgical field. Nevertheless, additional studies are required to determine whether the use of necklines is associated with better outcomes than those with conventional methods.

Reliability of Percutaneous Pulmonary Vent and Coronary Sinus Cardioplegia in the Setting of Minimally Invasive Aortic Valve Replacement: A Single-Center Experience

Paparella D.;
2017-01-01

Abstract

Objectives Evaluating the efficacy of 2 new percutaneous devices specifically designed to be placed through the right internal jugular vein, therefore named “necklines,” for achieving retrograde cardioplegia and pulmonary venting in the setting of minimally invasive aortic valve replacement (MIAVR). Design Case series. Setting University-affiliated private hospital. Participants Patients undergoing MIAVR. Interventions Necklines were placed by the anesthesiologist using transesophageal electrocardiography, with pressure guidance before the surgical procedure was initiated. Measurements and Main Results The records of 51 consecutive patients who underwent MIAVR with necklines placement were reviewed retrospectively. The access for MIAVR was through either a J-hemisternotomy or a right anterior thoracotomy. The efficacy of the 2 catheters, successful placement rate, time needed to deploy catheters, and perioperative complications were recorded. Necklines were placed successfully in all patients in 23±13 minutes. A total of 110 doses of retrograde cardioplegia were delivered at a mean flow rate of 173±35 mL/min and a mean pressure of 41±6 mmHg. The pulmonary catheter ensured venting of the heart that was graded by surgeons as “excellent” in 33 patients, “sufficient” in 12 patients, and “not adequate” in 2 patients. There were no major adverse events or deaths. Conclusions Necklines ensure effective retrograde cardioplegia and venting of the heart, provide optimal surgical vision and access during MIAVR, and allow surgeons to operate in an unobstructed surgical field. Nevertheless, additional studies are required to determine whether the use of necklines is associated with better outcomes than those with conventional methods.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11369/433506
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact