Background: Clips are endoscopic mechanical devices with tensile and closure strength that can approximate tissue and provide hemostasis through a tamponade effect. Clips are ubiquitously used in endoscopic practice, and numerous studies have validated the clinical efficacy of clips, with recent guidelines recommending them as a first-line intervention for recurrent and persistent nonvariceal gastrointestinal bleeding. However, the safety profile for these devices has yet to be delineated, thus, we aim to investigate this feature by examining the adverse events reported to the Food and Drug Administration. Methods: Postmarketing surveillance data from the Food and Drug Administration Manufacturer And User Facility Device Experience database were analyzed from January 2012 to January 2021. The Manufacturer And User Facility Device Experience database is a reporting software and does not independently verify the details of complications. Results: Two thousand five hundred forty reports were issued, of which 287 were patient adverse events and 2766 were device problems. Activation, separation, and positioning issues were most common. No consequences or clinically significant impact on patients were seen in 1968 reports. Foreign bodies were seen in 97 cases, hemorrhage in 57 cases, tissue damage in 42 cases, embedded clips in tissues/plaques in 16 cases, perforation in 15 cases, lacerations in 6 cases, and infection in 3 cases. Conclusions: While the most commonly reported device problems involved activation, separation, and positioning, most patients were clinically unaffected. Moreover, perforation and infection were exceedingly rare, further highlighting the safety profile of endoscopic clips.

Adverse Events of Endoscopic Clip Placement: A MAUDE Database Analysis

Facciorusso, Antonio;
2023-01-01

Abstract

Background: Clips are endoscopic mechanical devices with tensile and closure strength that can approximate tissue and provide hemostasis through a tamponade effect. Clips are ubiquitously used in endoscopic practice, and numerous studies have validated the clinical efficacy of clips, with recent guidelines recommending them as a first-line intervention for recurrent and persistent nonvariceal gastrointestinal bleeding. However, the safety profile for these devices has yet to be delineated, thus, we aim to investigate this feature by examining the adverse events reported to the Food and Drug Administration. Methods: Postmarketing surveillance data from the Food and Drug Administration Manufacturer And User Facility Device Experience database were analyzed from January 2012 to January 2021. The Manufacturer And User Facility Device Experience database is a reporting software and does not independently verify the details of complications. Results: Two thousand five hundred forty reports were issued, of which 287 were patient adverse events and 2766 were device problems. Activation, separation, and positioning issues were most common. No consequences or clinically significant impact on patients were seen in 1968 reports. Foreign bodies were seen in 97 cases, hemorrhage in 57 cases, tissue damage in 42 cases, embedded clips in tissues/plaques in 16 cases, perforation in 15 cases, lacerations in 6 cases, and infection in 3 cases. Conclusions: While the most commonly reported device problems involved activation, separation, and positioning, most patients were clinically unaffected. Moreover, perforation and infection were exceedingly rare, further highlighting the safety profile of endoscopic clips.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11369/429023
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact