Phthalate esters (PAEs) are commonly used as nonreactive plasticisers in vinyl plastics to increase the flexibility of plastic polymers. Numerous studies have indicated that the PAEs as a class of endocrine-disrupting chemicals. In addition, the studies have also shown that a major source of human exposure to phthalates is the diet. To date, the largest problem in PAEs analysis is the high blank value because PAEs are widely used in various applications and products. To overcome this shortcoming, gas purge microsyringe extraction (GP-MSE) was applied, which established a new and low-blank-value analytical method for PAE analysis to analyse PAEs in foodstuffs. In this study, GP-MSE was used as a clean-up method, and the overall recoveries ranged from 85.7 to 102.6%, and the RSD was less than 10%. More importantly, this method can overcome the problem of the high blank value in PAE analysis. This method was applied for measuring PAEs in 78 foodstuffs. The results showed that a wide variety of PAE concentrations were found in the different groups, and the content of PAEs (varies from 658 to 1610 ng g−1 fresh weight) is greatest in seafood. The concentrations were in the following order: DEHP > DBP > DEP ≈ DMP > BBP ≈ DNOP. Finally, the daily intake of PAEs was estimated for adults based on the levels of PAEs in foodstuffs. The total EDIdiet values of 3.2 and 12.9 μg kg−1 bw d−1 were calculated for DEHP based on the mean and highest concentrations in foodstuffs, respectively.

Monitoring of phthalates in foodstuffs using gas purge microsyringe extraction coupled with GC–MS

QUINTO, MAURIZIO;
2015-01-01

Abstract

Phthalate esters (PAEs) are commonly used as nonreactive plasticisers in vinyl plastics to increase the flexibility of plastic polymers. Numerous studies have indicated that the PAEs as a class of endocrine-disrupting chemicals. In addition, the studies have also shown that a major source of human exposure to phthalates is the diet. To date, the largest problem in PAEs analysis is the high blank value because PAEs are widely used in various applications and products. To overcome this shortcoming, gas purge microsyringe extraction (GP-MSE) was applied, which established a new and low-blank-value analytical method for PAE analysis to analyse PAEs in foodstuffs. In this study, GP-MSE was used as a clean-up method, and the overall recoveries ranged from 85.7 to 102.6%, and the RSD was less than 10%. More importantly, this method can overcome the problem of the high blank value in PAE analysis. This method was applied for measuring PAEs in 78 foodstuffs. The results showed that a wide variety of PAE concentrations were found in the different groups, and the content of PAEs (varies from 658 to 1610 ng g−1 fresh weight) is greatest in seafood. The concentrations were in the following order: DEHP > DBP > DEP ≈ DMP > BBP ≈ DNOP. Finally, the daily intake of PAEs was estimated for adults based on the levels of PAEs in foodstuffs. The total EDIdiet values of 3.2 and 12.9 μg kg−1 bw d−1 were calculated for DEHP based on the mean and highest concentrations in foodstuffs, respectively.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11369/323445
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 51
  • ???jsp.display-item.citation.isi??? 44
social impact